Enter the size and thickness of the slab, what it is for and your area's weathering potential. The calculator gives the concrete and base course to order and checks the slab against the residential code: thickness, strength and vapor retarder.

Your building department lists it in its Table R301.2.

Required where the slab is below grade, except on well-drained Group I soils.

Concrete to order

14.81 cubic yards

Area
1,200 sq ft
Concrete
400 cubic feet
Thickness
4 in: meets the 3-1/2 in minimum
Minimum strength
2,500 psi at 28 days
Base course, 4 in
14.81 cubic yards
Vapor retarder
1,200 sq ft of 10 mil, joints lapped 6 in

If the concrete may freeze and thaw during construction, it must be air-entrained.

2021 IRC (Seattle edition), Sections R402.2 and R506.

A 30 by 40 foot slab 4 inches thick takes 14.81 cubic yards of concrete. The residential code asks for at least 3-1/2 inches, and for a basement or interior slab at least 2,500 psi concrete.

Volume

The concrete is the area times the thickness: length × width in feet × thickness in inches ÷ 12 gives cubic feet, and ÷ 27 gives cubic yards, the unit ready-mixed concrete is ordered in. The base course under it is worked out the same way with its own depth.

What the code asks for

  • Thickness: concrete floors on the ground are at least 3-1/2 inches thick (Section R506.1).
  • Base: where the slab is below grade, a 4 inch base course of clean graded sand, gravel, crushed stone, crushed concrete or slag goes on the prepared subgrade, except on well-drained Group I soils (R506.2.2).
  • Vapor retarder: in Seattle's edition, at least 10 mil, meeting ASTM E1745 Class A, with joints lapped 6 inches, between the slab and the base. It is not required for garages, unheated accessory buildings, carports, small unheated storage rooms, or driveways, walks and patios (R506.2.3).
  • Strength: from Table R402.2, below.

Concrete strength

Minimum specified compressive strength at 28 days, psi, by weathering potential (Table R402.2).
SlabNegligibleModerateSevere
Basement and interior slabs, except garage floors2,5002,5002,500
Garage floors, porches and carport slabs exposed to the weather2,5003,0003,500

The 3,000 and 3,500 psi slabs must be air-entrained, with 5 to 7 percent air; a steel-troweled garage floor may have as little as 3 percent if its strength is raised to 4,000 psi. An interior slab in a severe area must be air-entrained if it may freeze and thaw during construction. Your building department gives the weathering potential in its Table R301.2.

A worked example

A basement floor measures 30 by 40 feet and is poured 4 inches thick: 1,200 × 4 ÷ 12 = 400 cubic feet, or 14.81 cubic yards. The 4 inch base course under it is another 14.81 cubic yards, and the vapor retarder covers 1,200 square feet plus its laps. Even in a severe weathering area, an interior slab needs 2,500 psi concrete.

Questions people ask

How thick does a concrete slab have to be?

The residential code's minimum for a concrete floor on the ground is 3-1/2 inches. Expansive soils have their own rules.

How many cubic yards for a 20 by 20 slab?

At 4 inches thick, 133.3 cubic feet, or 4.94 cubic yards.

What strength of concrete does a garage floor need?

Under Table R402.2, 2,500 psi where weathering is negligible, 3,000 psi where it is moderate and 3,500 psi where it is severe, air-entrained in the last two cases.

Sources