Sill & Rafter

Plumbing & Water · Calculator

Septic Drain Field Calculator

Choose your state, enter the bedrooms and the soil result from your site evaluation or percolation test, and the trench width. The calculator applies that state's rule to find the absorption area of a conventional gravity trench system and the length of trench it takes.

Clothes washer, dishwasher, water softener, bathtub over 40 gallons, garbage disposal, self-cleaning furnace humidifier.

From the site evaluation: the most restrictive horizon along the trench or within 2 ft below it.

The most restrictive texture within 24 in below the drain field.

From the percolation tests on your site; in Pennsylvania, the average of the tests.

Matters only at 0.1 to 5 minutes per inch.

As the rule calls it, in inches; the minimum is 6.

Trench length needed

278 ft

Design flow
400 gallons per day
Table A
1.39 sq ft per gpd
Bottom area
556 sq ft
Trenches, at most 100 ft each, two at least
3

25 Pa. Code §73.16 Table A, §73.42, §73.43 and §73.52.

A drain field is sized from the design flow and how fast the soil takes water. In Pennsylvania, a 3 bedroom house on soil that percolates at 20 minutes per inch needs 556 square feet of trench bottom, 278 feet of trench 2 feet wide.

How each state sizes it

Every state divides the design flow by a soil loading rate, in gallons a day per square foot, but each asks for a different soil result and counts a different part of the trench:

StateSoil resultArea counted
Texassoil classbottom and 1 ft of sidewall
Floridasoil texturebottom
Pennsylvaniapercolation ratebottom
Minnesotapercolation ratebottom, reduced for deep sidewall
North Carolinasoil groupinfiltrative surface

The design flow is the same one each state uses for the septic tank; the septic tank size calculator explains it. Florida sizes the drain field on at least 200 gallons a day.

Texas

The soil class comes from the texture: Class Ib, sand and loamy sand with 30 percent gravel or less, takes 0.38 gallons a day per square foot; Class II, sandy loam and loam, 0.25; Class III, the silts, clay loams and sandy clay, 0.20. Class Ia, sandy soils with more than 30 percent gravel, and Class IV, silty clay and clay, are not suitable for a standard drain field, and Class II or III soils that contain gravel need a sieve analysis. The absorptive area counts the bottom of the excavation plus 1 foot of sidewall around it, so for an excavation 3 feet wide or less its length is the area divided by the width plus 2. Excavations are at least 18 inches wide, no longer than 150 feet each and 3 feet apart.

Florida

Table III of the rule gives 0.80 gallons a day per square foot of trench bottom for sands and loamy sands, 0.65 for loams, silt loams and sandy clay loam, and 0.35 for clay loams, sandy and silty clays and silt; clay, organic soils, hardpan and bedrock are severely limited, and so are gravel, fractured rock, oolitic limestone and coarse sand with a wet-season water table within 48 inches. Florida sizes by texture; a measured percolation rate is used with the table by the Department, together with other factors. Trenches are no more than 36 inches wide at the bottom, drain lines no longer than 100 feet. A drain field over 1,000 square feet needs low-pressure dosing, or, up to 2,000 square feet, two equal drain fields of no more than 1,000 each.

Pennsylvania

Table A gives square feet of trench bottom per gallon a day from the average percolation rate: 1.19 from 6 to 15 minutes per inch, rising to 2.66 at 60 minutes. From 61 to 90 minutes per inch the field needs pressure dosing, and soils faster than 6 or slower than 90 minutes are not suitable for a standard trench. A field has at least two trenches, 12 to 72 inches wide with 5 feet of undisturbed earth between them; gravity laterals are no longer than 100 feet, and a field over 2,500 square feet needs pressure distribution.

Minnesota

Table IXa gives the loading rate for septic tank effluent by percolation rate: 1.2 gallons a day per square foot at 0.1 to 5 minutes per inch, 0.6 for fine sand and loamy fine sand, then 0.78, 0.6, 0.5 and 0.45 up to 60 minutes; slower soils get no rate here. Trenches with 12 to 17, 18 to 23 or 24 inches of sidewall absorption may reduce their bottom area by 20, 34 or 40 percent, but not 40 percent at 1.2. Trenches are no more than 36 inches wide and use serial distribution, and the fastest soils need one of three extra measures.

North Carolina

The long-term acceptance rate, or LTAR, depends on the soil group: 0.8 to 1.2 for sands, 0.6 to 0.8 for coarse loams, 0.3 to 0.6 for fine loams and 0.1 to 0.4 for clays. The authorized agent assigns the rate within that range from the site, so the calculator gives the area as a range, starting from the mean of the range that the rule sets as the cap for a facility with a full kitchen. The trench length is the area divided by an equivalent trench width, which the rule does not define for a conventional gravel trench, so the calculator stops at the area. Conventional trenches are 2 to 3 feet wide, and lateral lengths over 750 feet in total need a dosing system.

A worked example

A three-bedroom house in Pennsylvania is designed for 400 gallons a day. The percolation tests average 20 minutes per inch, so Table A gives (20 − 15) × 0.040 + 1.19 = 1.39 square feet per gallon a day: 400 × 1.39 = 556 square feet of trench bottom. With trenches 2 feet wide that is 278 feet of trench, in 3 trenches of no more than 100 feet.

Questions people ask

How long does a septic drain field need to be?

It depends on the state, the soil and the trench width. In Pennsylvania, a three-bedroom house on soil that percolates at 20 minutes per inch needs 556 square feet of trench bottom, 278 feet of trench 2 feet wide.

How does the percolation rate change the size?

The slower the soil takes water, the more area it needs. In Pennsylvania, every gallon a day needs 1.19 square feet at 6 to 15 minutes per inch and 2.66 square feet at 60.

Do the trench sidewalls count?

In Texas, 1 foot of sidewall around the excavation counts; in Florida, Pennsylvania and North Carolina, the area is the bottom or the infiltrative surface; in Minnesota, deeper sidewalls allow a smaller bottom area.

Sources