Heating, Cooling & Energy · Calculator
R-Value Calculator
Enter each layer's R-value, as printed on the product, or its thickness and R-value per inch. The calculator adds them up, gives the U-value and, for an area and a temperature difference, the heat that flows through.
Total R-value
R-18
- Layer 1
- R-13
- Layer 2
- R-5
- U-value
- 0.056 Btu/h·ft²·°F
- Heat flow through 100 sq ft at 50 °F
- 278 Btu/h
Layers in series add their R-values; framing that bridges the insulation lowers the real figure, so this is the R-value through the insulated part.
Arithmetic of R-values in series.
R-values of layers in series add up. A layer rated R-13 and another rated R-5 make R-18, a U-value of 0.056.
Adding layers
When heat has to pass through one layer after another, their R-values add: two layers of R-10 make R-20. Enter each layer either as a total R-value, as printed on the product, or as a thickness and an R-value per inch, which the calculator multiplies.
U-value and heat flow
The U-value is 1 divided by the total R-value, in Btu per hour, square foot and degree Fahrenheit. Multiply it by an area and by the difference between inside and outside temperatures and you get the heat that flows through that area each hour.
A worked example
A wall has batts labeled R-13 and a foam board labeled R-5 over them: R-13 + R-5 = R-18, a U-value of 1 ÷ 18 = 0.056. Through 100 square feet of that wall, with 50 °F more inside than out, 100 × 50 ÷ 18 = 277.7778 Btu flow each hour.
What it leaves out
Studs, joists and other framing cross the insulation and carry more heat than the insulation between them, so a whole wall does worse than the R-value through its insulated part. The calculator adds only the layers you enter.
Questions people ask
How do I calculate the total R-value of a wall?
Add the R-values of the layers the heat passes through, one after another. For a layer given per inch, multiply by its thickness first.
How do I convert R-value to U-value?
Divide 1 by the R-value: R-20 is a U-value of 0.05.