Sill & Rafter

Heating, Cooling & Energy · Calculator

HSPF2 Savings Calculator

Enter the electricity your heat pump uses for heating in a year, or the heat your house needs, then the HSPF2 of your current unit and of the new one. The calculator works out the electricity and the money the better rating saves.

From your bills: winter months minus a typical month with no heating or cooling.

From an energy audit or load calculation.

On the yellow EnergyGuide label or the AHRI certificate. An older unit may only show HSPF, from an earlier test: do not mix the two.

What each extra kWh costs you, without the fixed monthly charge.

Saved on heating

$120 a year

Electricity saved
706 kWh (11.8%)
Heat delivered in the season
45 million Btu
At HSPF2 7.5
6,000 kWh
At HSPF2 8.5
5,294 kWh
Seasonal average COP
2.2 → 2.49
Heating cost
$1,020 → $900

HSPF2 is measured for one standard climate. The calculator assumes the saving follows the ratio of the two ratings; in a climate unlike the test's the real figures will differ.

HSPF2 as defined in 10 CFR 430, Appendix M1; 3,412 Btu per kWh (EIA).

A heat pump using 6,000 kWh a year for heating at HSPF2 7.5 would use 5,294.1176 kWh at HSPF2 8.5: 705.8824 kWh less, about $120 a year at 0.17 dollars per kWh.

What HSPF2 measures

The federal test procedure defines HSPF2 as the total heat a heat pump delivers over a heating season, in Btu, divided by the electricity it uses in the same season, in watt-hours. The season is a standard one, the test's Region IV climate, so the rating compares units fairly but is not a forecast for your house. One kWh is 3,412 Btu, so dividing HSPF2 by 3.412 gives the heat pump's average coefficient of performance over that season: HSPF2 7.5 is a COP of about 2.2.

Minimums and ENERGY STAR

Heat pumpFederal minimumENERGY STAR
Split system7.57.8
Single-package unit6.77.2
Cold climate, ductless split7.58.5
Cold climate, ducted split or package7.5 or 6.78.1

The federal minimums apply to heat pumps made from January 1, 2023. ENERGY STAR's cold-climate heat pumps must also reach a COP of at least 1.75 at 5 °F.

How the saving is worked out

The house needs the same heat whichever unit makes it, and a heat pump's electricity is that heat divided by its HSPF2. So the electricity saved is the share 1 − old HSPF2 ÷ new HSPF2 of what you use now. Starting from your bills, the calculator first finds the season's heat (your kWh × 1,000 × the current HSPF2) and then the electricity the new unit would need for it.

The saving follows the ratio of the two ratings, which is a simplification: two units with the same HSPF2 can behave differently in a much colder or milder climate than the test's.

HSPF and HSPF2 are different numbers

Since 2023 heat pumps are rated with the federal test procedure in Appendix M1, which gives HSPF2. Older units carry an HSPF from the earlier Appendix M test. The two tests differ, so compare HSPF2 with HSPF2.

Questions people ask

What is a good HSPF2 rating?

The federal minimum for a split heat pump is 7.5 and ENERGY STAR asks for 7.8. Cold-climate ENERGY STAR models reach 8.1 ducted and 8.5 ductless.

How much does a higher HSPF2 save?

The share 1 − old ÷ new of the heating electricity: going from 7.5 to 8.5 saves about 11.8 percent.

How do you convert HSPF2 to COP?

Divide by 3.412. The result is the average COP over the test's heating season, not the COP at any one temperature.