Sill & Rafter

Roof & Exterior · Calculator

Window U-Factor and SHGC by Frame and Glazing

Choose the frame, the number of panes and the glass. The calculator gives the default ratings the energy code assigns to a window without an NFRC label, its R-value, and how it compares with the ENERGY STAR limit for a zone.

Default U-factor

0.55

Default SHGC
0.7
Default VT
0.6
R-value of the whole window
1.82 (1 ÷ U)

These defaults apply only to products without an NFRC label; a labeled window uses its own ratings.

ENERGY STAR in the North-Central zone asks for a U-factor of 0.25 or less: this default does not.

2021 Seattle Energy Code, residential, Tables R303.1.3(1) and R303.1.3(3).

Without an NFRC label, a window gets the energy code's default ratings. A double-pane window in a nonmetal frame is assigned a U-factor of 0.55 and an SHGC of 0.7.

When defaults apply

Section R303.1.3 of the energy code asks for U-factors determined under NFRC 100 and SHGC and visible transmittance under NFRC 200, by an accredited, independent laboratory, labeled and certified by the maker. A product without such a label is assigned a default from the code's tables. This page uses the 2021 Seattle Energy Code, which is Washington State's code with Seattle's amendments.

The default tables

Default U-factor for windows and glass doors, Table R303.1.3(1).
FrameSingleDouble
Metal1.200.80
Metal, thermal break1.100.65
Nonmetal or metal clad0.950.55
Glazed block0.60

Table R303.1.3(3) sets the default SHGC at 0.8 for single clear glass, 0.7 for single tinted or double clear and 0.6 for double tinted or glazed block, and the visible transmittance at 0.6 for clear glass and glazed block and 0.3 for tinted glass. A metal thermal break frame must meet minimum design characteristics set out in a footnote to the table.

A worked example

An old double-pane window in a wood frame has no NFRC label. The energy code assigns it a U-factor of 0.55, an SHGC of 0.7 and a visible transmittance of 0.6. Its R-value is 1 ÷ 0.55 = 1.8. ENERGY STAR in the North-Central zone asks for a U-factor of 0.25 or less, so the default is far from it.

U-factor and R-value

The U-factor is the inverse of the R-value of the whole window, frame included: a U-factor of 0.55 is about R-1.8. ENERGY STAR's most lenient limit, in the Southern zone, is a U-factor of 0.32, so none of the code's defaults reaches it; a window qualifies only with its own NFRC ratings.

Questions people ask

What is the U-factor of a double-pane window?

With an NFRC label, whatever the label says. Without one, the energy code assigns 0.55 in a nonmetal or metal-clad frame, 0.65 in metal with a thermal break and 0.80 in plain metal.

What is the R-value of a single-pane window?

The code's default U-factor for a single pane in a nonmetal frame is 0.95, about R-1.05; in a metal frame, 1.20, about R-0.83.

Can an unlabeled window be ENERGY STAR?

No. ENERGY STAR certification rests on NFRC ratings, and none of the code's default U-factors is below ENERGY STAR's limits.