Sill & Rafter

Roof & Exterior · Calculator

Insulated Garage Door Heat Loss Calculator

Enter the size of the door, the U-factor of your current door and of the insulated one, and the temperatures inside the garage and outdoors. The calculator gives the heat each door lets through and the difference, the honest starting point for deciding whether insulation pays for you.

From the door maker's data. For a plain uninsulated steel door, 1.15 is the default in Washington's energy code.

The tested U-factor from the maker or the ICC-ES listing, not the R-value.

Measure it: an attached garage sits somewhere between indoors and outdoors.

Heat flow saved

2,890 Btu/h

Door area
112 sq ft
Temperature difference
30 °F
Through the current door
3,864 Btu/h
Through the insulated door
974 Btu/h
Over 24 hours
69,350 Btu, or 20.3 kWh of heat

This is conduction through the door only: air leaking around the door and sun on it are not part of a U-factor.

The heat lost is heat taken from the garage. How much of it your heating system pays for depends on how warm you keep the garage and on the wall between it and the house.

U × area × temperature difference; tested U-factors under ANSI/DASMA 105.

On a 20 °F day with the garage at 50 °F, a 16 by 7 foot door with a U-factor of 1.15 lets through 3,864 Btu an hour; an insulated door at 0.29 lets through 974.4, 2,889.6 Btu an hour less.

Use the U-factor, not the R-value

Garage door ads quote R-values, but the Door and Access Systems Manufacturers Association (DASMA) explains that for garage doors the R-value and the U-factor are not reciprocals. The R-value is calculated for the insulated section alone; the U-factor is tested on the whole door, joints, frame and all, under the ANSI/DASMA 105 method. Heat flow through a door is its U-factor × its area × the temperature difference, so the U-factor is the number to use, and lower is better: DASMA notes that a door with a U-factor of 0.20 is twice as efficient as one at 0.40.

Tested U-factors

Makers in DASMA's verification program have their U-factors listed by ICC Evaluation Service. A few from those listings:

DoorU-factor
Wayne Dalton 9100 and 9605, polyurethane0.35
Wayne Dalton 9405, polyurethane0.29
Wayne Dalton 8500, polyurethane0.18
Overhead Door Thermacore models0.14 to 0.27
Uninsulated steel door (default value in Washington's energy code, not a test)1.15

Uninsulated doors are not in the verification program, which is why the comparison uses a code default for them.

What decides whether it pays

The garage's own temperature. An insulated door saves heat only while the garage is warmer than outdoors, and it saves your money only if you pay to keep it that way, directly or through the wall it shares with the house. ENERGY STAR has no specification for garage doors, and Clopay notes that energy codes reach garage doors only when the garage is heated or cooled space. Measure the garage temperature on a cold day and enter it; we found no official figure for a typical attached garage.

What the number leaves out

U-factors cover conduction only. DASMA's program does not rate air leaking around the door or heat from the sun, so weatherstripping and the bottom seal are a separate question from insulation.

Questions people ask

Is an insulated garage door worth it?

If you heat the garage or it shares a wall with living space, it cuts the heat lost through the door roughly in proportion to the U-factors. If the garage stays near the outdoor temperature, the door saves little.

What is a good U-factor for a garage door?

Lower is better. Tested insulated doors in DASMA's program run from about 0.14 to 0.35; an uninsulated steel door is around 1.15 by code default.

Why is the R-value not 1 divided by the U-factor?

Because the R-value describes the insulated section only, while the U-factor is tested on the whole door, including its joints and edges.

Sources