Sill & Rafter

Roof & Exterior · Calculator

Hearth Extension and Chimney Height Calculator

Choose what to check. For the hearth, enter the size of the fireplace opening; for the chimney, the roof pitch and the distance to the ridge. The calculator applies the residential code's rules for masonry fireplaces and chimneys.

Measured level, from the upslope side of the chimney.

Optional: a dormer, a higher wall or another roof, by how much it rises above the point where the chimney passes through the roof.

Hearth extension, at least

60 × 20 in

Fireplace opening
7.25 sq ft, 6 sq ft or more
In front of the opening
at least 20 in
Beyond each side
at least 12 in

The hearth extension must be at least 2 in thick, or 3/8 in of brick, concrete, stone or tile where the bottom of the firebox opening is at least 8 in above it.

Combustible framing stays at least 2 in from the front and sides of a masonry fireplace and 4 in from its back.

2021 IRC (Seattle edition), Sections R1001.9 to R1001.11.

A fireplace opening of 36 by 29 inches is 7.25 square feet, so the hearth extension must reach at least 20 inches in front of it and 12 inches beyond each side.

Hearth extension

The hearth extension is the noncombustible floor in front of and beside the fireplace opening. Section R1001.10 sets its size from the opening: at least 16 inches in front and 8 inches beyond each side, or 20 and 12 inches where the opening is 6 square feet or larger. Section R1001.9 asks for a hearth at least 4 inches thick and a hearth extension at least 2 inches thick; where the bottom of the firebox opening is at least 8 inches above the extension, 3/8 inch of brick, concrete, stone, tile or another approved noncombustible material is enough.

Clearances to combustibles

WhereSectionAirspace
Masonry fireplace, front and sidesR1001.112 in
Masonry fireplace, backR1001.114 in
Masonry chimney inside the building or in an exterior wallR1003.182 in
Masonry chimney entirely outside the wallsR1003.181 in

The airspace may not be filled, except with the fireblocking the code requires. Exposed combustible trim and the edges of siding, flooring or drywall may meet the fireplace sides and hearth extension if they stay at least 12 inches from the inside of the firebox lining. Fireplaces and chimney liners listed and labeled for contact with combustibles follow their listing.

A worked example

A masonry fireplace has an opening 36 inches wide and 29 inches tall: 36 × 29 ÷ 144 = 7.25 square feet, more than 6. The hearth extension must therefore reach at least 20 inches in front of the opening and 12 inches beyond each side: at least 60 by 20 inches, and at least 2 inches thick.

Chimney height above the roof

Section R1003.9 sets two heights for a chimney, and the higher one governs: at least 3 feet above the highest point where it passes through the roof, and at least 2 feet higher than any part of the building within 10 feet. The calculator measures the roof's rise level from the upslope side of the chimney, up to the ridge or 10 feet, whichever is closer: on a 6 in 12 roof with the ridge 6 feet away, the roof rises 3 feet, so the chimney must reach 5 feet above the point where it passes through the roof. Enter any dormer, higher wall or other roof within 10 feet as well.

Factory-built fireplaces and chimneys

These rules are for masonry. Factory-built fireplaces and chimneys must be listed and labeled and installed, and chimneys terminated, as their makers' instructions say (Sections R1004.1 and R1005.1).

Questions people ask

How far does a hearth have to extend?

At least 16 inches in front of the fireplace opening and 8 inches beyond each side; 20 and 12 inches if the opening is 6 square feet or larger.

How tall does a chimney need to be above the roof?

At least 3 feet above the highest point where it passes through the roof, and at least 2 feet higher than any part of the building within 10 feet.

How much clearance does a masonry chimney need from framing?

An airspace of 2 inches where it is inside the building or in an exterior wall, and 1 inch where it is entirely outside the walls.

Sources