Roof & Exterior · Calculator
Gutter and Downspout Size Calculator
Enter the roof area that drains into a gutter, your local 100-year rainfall rate and the number of downspouts. The calculator works out the peak flow the way the plumbing code does and finds the smallest downspout and gutter in the code's tables that can carry it.
Peak flow off this roof
31.2 gpm
- Area counted
- 1,000 sq ft
- Rainfall
- 3 in/h
- Smallest gutter in Table 1106.6
- 8 in semicircular, 172 gpm
- Each downspout carries
- 15.6 gpm
- Smallest downspout in Table 1106.3
- 2 in, 30 gpm
- 2 × 3 in downspout
- enough (credited 30 gpm)
- 3 × 4 in downspout
- enough (credited 92 gpm)
IPC 2021 Section 1106: Equation 11-1, Tables 1106.3 and 1106.6. 2 × 3 and 3 × 4 downspouts get the capacity of the largest listed size that fits inside them.
The plumbing code sizes roof drainage from the heaviest hour of rain expected once in 100 years. A 1,000 square foot roof at 3 inches per hour sheds 31.2 gallons per minute, so each of 2 downspouts carries 15.6 gallons per minute.
How the code sizes roof drainage
Section 1106 of the International Plumbing Code works in three steps:
- Take the rainfall rate of the 100-year, 1-hour storm for the site (Section 1106.1), in inches per hour.
- Turn it into a flow with Equation 11-1: gallons per minute = rainfall in inches per hour × roof area in square feet × 0.0104.
- Pick downspouts (the code calls them vertical leaders) from Table 1106.3 and gutters from Table 1106.6, so that none carries more than its listed capacity.
The 0.0104 is simple arithmetic: an inch of rain an hour falling on one square foot is about a hundredth of a gallon a minute.
Finding your rainfall rate
NOAA's Atlas 14 Precipitation Frequency Data Server gives the figure for any address in most of the country: open the map, pick your location, and read the row for 60 minutes in the column for 100 years. For downtown Atlanta, for example, it is 3.25 inches. The code's own maps and its informative Appendix B list older figures for some cities, Atlanta at 3.7, and the code also accepts rates from approved local weather data, so ask your building department which one it uses.
Measuring the roof area
Use the area as seen from above, not the area along the slope: a 40 by 25 foot side of a roof counts as 1,000 square feet however steep it is. Count only the part of the roof that drains into the gutter you are sizing. If a wall above that roof sheds rain onto it, such as a second-story wall over a porch roof, Section 1106.4 adds half of the wall's area; the calculator does that for you.
A worked example
One side of a house roof covers 1,000 square feet seen from above, and the local 100-year, 1-hour rainfall is 3 inches. Equation 11-1 gives 3 × 1,000 × 0.0104 = 31.2 gallons per minute. With 2 downspouts, each carries 15.6 gallons per minute: Table 1106.3 accepts a 2 in round leader, and a 2 × 3 downspout, credited with 30 gallons per minute, is enough. The gutter itself hangs at the usual house pitch, flatter than the table, so its size comes from the maker's data.
The catch with house gutters
Table 1106.6 lists gutters at slopes from 1/16 to 1/2 inch per foot. House gutters are usually hung much flatter: gutter makers' instructions call for about 1/4 inch every 10 feet, which is 1/40 inch per foot. The table also lists only semicircular gutters and rectangular ones given by width and depth, not the K-style profile most houses have. So for a typical house gutter the code table cannot give a size; use the capacity data of the gutter maker, and choose Flatter in the calculator to see only the downspout sizing, which does not depend on the gutter's slope.
2 × 3 and 3 × 4 downspouts
The two most common rectangular downspouts on houses, 2 × 3 and 3 × 4 inches, are not in Table 1106.3. The calculator credits each with the capacity of the largest listed size that fits entirely inside it: 30 gallons per minute for a 2 × 3, since a 2 inch round or a 1-1/2 × 2-1/2 inch leader fits inside it, and 92 for a 3 × 4, which contains a 2 × 4 and a 2-1/2 × 3. That never overstates what the downspout can carry.
Questions people ask
How many square feet can a 2x3 downspout handle?
With the conservative credit of 30 gallons per minute, about 961 square feet of roof at a rainfall rate of 3 inches per hour. Heavier local rainfall means less area per downspout.
And a 3x4 downspout?
Credited with 92 gallons per minute, about 2,948 square feet at 3 inches per hour.
Is the rainfall rate the same everywhere?
No. The 100-year, 1-hour rate varies a lot across the country, which is why the code asks for the local figure. Read it from NOAA Atlas 14 or ask your building department.
Sources
- 2021 International Plumbing Code, Chapter 11 (UpCodes, Colorado edition) — Sections 1106.1–1106.6, Equation 11-1, Tables 1106.3 and 1106.6
- NYC 2022 Plumbing Code, Chapter 11: Storm Drainage — based on the 2021 IPC; same Tables 1106.3 and 1106.6
- NOAA Atlas 14 Precipitation Frequency Data Server — 100-year, 60-minute rainfall for any location
- Amerimax: metal gutter installation instructions (2010) — about 1/4 in of fall every 10 ft