Sill & Rafter

Roof & Exterior · Calculator

Fireplace Flue Size Calculator

Enter the width and height of the fireplace opening. The calculator applies the residential code's ratios between flue and opening and picks the smallest standard round and square clay liners that meet them. It can also check a flue you already have.

The front opening of the firebox, inside the masonry.

From the liner tables on this page, the maker, or measured inside the flue.

Smallest flue liner

10-3/4 in round

Fireplace opening
36 × 29 in = 1,044 sq in
Round flue, 1/12
at least 87 sq in: 10-3/4 in liner (90 sq in)
Square flue, 1/10
at least 104.4 sq in: 13 × 13 in liner (127 sq in)
Long rectangular flue, 1/8
at least 130.5 sq in

IRC 2021 Section R1003.15.1 and Tables R1003.14(1) and R1003.14(2).

A masonry fireplace draws properly only if its flue is large enough for the opening. A 36 by 29 inch opening is 1,044 square inches, so the code asks for a round flue of at least 87 square inches or a square one of at least 104.4.

The code's ratios

Section R1003.15 of the International Residential Code gives two ways to size the flue of a masonry fireplace. The first, which this calculator uses, ties the flue to the fireplace opening:

  • a round flue at least 1/12 of the opening area;
  • a square flue, or a rectangular one less than 2 to 1, at least 1/10;
  • a rectangular flue 2 to 1 or longer at least 1/8.

Round flues get the smallest ratio because smoke rises in a spiral and uses a round section best; long, narrow flues need the most area. The second way, Option 2 in Section R1003.15.2, reads the flue size from a chart that also accounts for the chimney's height, measured from the firebox floor to the top of the flue. A tall chimney draws harder, so Option 2 can allow a different size; this calculator does not apply it.

Measuring the opening

Measure the front opening of the firebox, inside the masonry: the width at the opening and the height from the hearth to the underside of the lintel. Multiply them to get the area in square inches.

A worked example

A fireplace opening 36 inches wide and 29 inches tall is 1,044 square inches. A round flue needs at least 1/12 of that, 87 square inches, and the smallest round liner in the code table that provides it is the 10-3/4 in one, with 90 square inches. A square flue needs 1/10, 104.4 square inches: a 12 × 12 inch liner, at 102 square inches, falls just short, so the answer is the 13 × 13 in, with 127.

Standard liner sizes

Clay flue liners come in standard sizes. The code's Table R1003.14(1) lists round liners by inside diameter, based on ASTM C315, and Table R1003.14(2) lists square and rectangular liners by outside nominal dimensions, each with its net inside area. The calculator compares the required area with those net areas, not with the outside size. The code also accepts areas given by the liner's maker or measured in the field, which is how you check an old chimney: enter the net inside area of your flue in the calculator.

For rectangular liners, the calculator takes the 2 to 1 limit from the liner's nominal dimensions.

Inserts and stoves

The ratios above are for open masonry fireplaces. When a wood stove or a fireplace insert vents into the chimney, Section R1003.14 applies instead: the flue may not be smaller than the appliance's connector, and the appliance maker's instructions usually set the liner size.

Questions people ask

What size flue does a 36 inch fireplace need?

It depends on the height of the opening too. A 36 by 29 inch opening needs a round flue of at least 87 square inches, a 10-3/4 in round liner, or a square one of at least 104.4, a 13 × 13 in liner, under IRC Section R1003.15.1.

Why do round flues need less area?

Because the code sets the round flue at 1/12 of the opening, against 1/10 for square flues and 1/8 for long rectangular ones: a round section carries smoke with less wasted space in the corners.

My chimney flue is smaller than this. Is that a problem?

An undersized flue can let smoke spill into the room. The code's second sizing option, based on chimney height, may still accept it, so have a chimney professional check it before you use the fireplace.

Sources