Roof & Exterior · Calculator
ENERGY STAR Window Checker
Enter the U-factor and solar heat gain coefficient from the window's NFRC label and choose your ENERGY STAR climate zone. The calculator compares them with the ENERGY STAR criteria for residential windows.
ENERGY STAR criteria
Does not meet them
- Zone
- North-Central
- Criteria
- U ≤ 0.25 with SHGC ≤ 0.40
- This window
- U 0.27, SHGC 0.30
The U-factor is too high for this zone.
Meeting the numbers is not certification: an ENERGY STAR window is made by an ENERGY STAR partner and tested, certified and verified by NFRC. Look for the label.
ENERGY STAR Certification Criteria for Residential Windows (October 2023 table).
ENERGY STAR sets a maximum U-factor for each climate zone, and a maximum or minimum SHGC. In the North-Central zone, for example, a window qualifies with a U-factor of 0.25 or less and an SHGC of 0.40 or less.
Reading the NFRC label
ENERGY STAR bases its criteria on ratings certified by the National Fenestration Rating Council, printed on the window's NFRC label; without that label, NFRC says, the product is not certified. NFRC's own guide to the label explains the numbers:
- U-factor measures how well a product keeps heat from escaping. Ratings generally fall between 0.20 and 1.20, and the lower, the better it keeps heat in, which matters most in winter.
- Solar heat gain coefficient, or SHGC, measures how well it blocks heat from the sun, as a number between 0 and 1: the lower, the better it blocks unwanted heat, which matters most in summer.
- Visible transmittance, or VT, measures how much light comes through, also between 0 and 1: the higher, the more daylight.
- Air leakage measures how much outside air comes in through the product, typically between 0.1 and 0.3; the lower, the better. It is optional on the label.
The label also carries a CPD number for NFRC's Certified Products Directory. ENERGY STAR uses the U-factor and the SHGC, with a limit on air leakage; it caps the U-factor in every zone, caps the SHGC in the other zones and sets a minimum for it in the Northern zone.
The criteria by zone
| Zone | U-factor | SHGC |
|---|---|---|
| Northern | ≤ 0.22 | ≥ 0.17 |
| Northern, equivalent | 0.23–0.24 | ≥ 0.35 |
| Northern, equivalent | 0.25–0.26 | ≥ 0.40 |
| North-Central | ≤ 0.25 | ≤ 0.40 |
| South-Central | ≤ 0.28 | ≤ 0.23 |
| Southern | ≤ 0.32 | ≤ 0.23 |
In the Northern zone, a window with a slightly higher U-factor still qualifies if it lets in more of the sun's heat; ENERGY STAR calls this equivalent energy performance. Air leakage must also be 0.3 cubic feet per minute per square foot or less. The calculator compares ratings at two decimals, as the criteria are printed.
A worked example
A double-hung window's NFRC label gives a U-factor of 0.27 and an SHGC of 0.31. In the North-Central zone ENERGY STAR asks for a U-factor of 0.25 or less with an SHGC of 0.40 or less: the SHGC fits, but the U-factor is too high, so the window does not meet the criteria there. In the South-Central zone, with a U-factor limit of 0.28 and an SHGC limit of 0.23, it would fail on the SHGC instead.
Finding your zone
ENERGY STAR uses four zones of its own for windows, from Northern to Southern. Use the zone map or the search on ENERGY STAR's window criteria page to find yours.
Certified, not just compliant
Meeting the numbers is not the same as being certified. ENERGY STAR certified windows are made by an ENERGY STAR partner and independently tested, certified and verified by NFRC. Look for the ENERGY STAR label.
Questions people ask
What U-factor does an ENERGY STAR window need?
It depends on the zone: 0.22 or less in the Northern zone, 0.25 in North-Central, 0.28 in South-Central and 0.32 in Southern. In the Northern zone, 0.23 to 0.26 can also qualify with a high enough SHGC.
Is a lower SHGC always better?
Not for ENERGY STAR in every zone. It caps the SHGC at 0.23 in the South-Central and Southern zones and at 0.40 in North-Central, but in the Northern zone it sets a minimum of 0.17, and a higher SHGC lets windows with a U-factor of 0.23 to 0.26 qualify there.
Where do I find my window's U-factor and SHGC?
On the NFRC label, the sticker certified by the National Fenestration Rating Council, or in the maker's product data.
Sources
- National Fenestration Rating Council: Understanding the NFRC Label (2013) — what the U-factor, SHGC, visible transmittance and air leakage measure, and their usual ranges
- ENERGY STAR: Residential Windows, Doors and Skylights, Key Product Criteria — criteria based on NFRC ratings, by climate zone; zone search
- ENERGY STAR Certification Criteria for Residential Windows (table, October 2023) — U-factor and SHGC by zone, Northern equivalent-performance options, air leakage ≤ 0.3 cfm/ft²