Roof & Exterior · Calculator
Egress Window Calculator
Enter the net clear opening of the window when it is fully open, and the height of its sill above the floor. The calculator checks it against the four requirements of the 2021 International Residential Code and, for a basement window, the size of the window well.
Emergency escape opening
Meets the size rules
- Net clear opening
- 6 sq ft: the minimum is 5.7, met
- Height, at least 24 in
- 36 in: met
- Width, at least 20 in
- 24 in: met
- Sill, at most 44 in above the floor
- 40 in: met
This checks the sizes only. The opening must also open from the inside without keys, tools or special knowledge and lead to a yard, court or public way.
2021 IRC (Seattle edition), Sections R310.1, R310.2 and R310.4; definition of a grade-floor opening in Chapter 2.
An escape window must open to at least 5.7 square feet, with a clear opening at least 24 inches high and 20 inches wide. A 24 by 36 inch opening gives 6 square feet.
Which rooms need one
Section R310.1 requires at least one operable emergency escape and rescue opening in basements, habitable attics and every sleeping room; where a basement has sleeping rooms, each of them needs one. It must open from the inside without keys, tools or special knowledge, and lead to a yard, court or public way.
The size limits
| Requirement | Section | Limit |
|---|---|---|
| Net clear opening | R310.2.1 | at least 5.7 sq ft |
| Grade-floor opening | R310.2.1 | at least 5 sq ft |
| Clear height | R310.2.2 | at least 24 in |
| Clear width | R310.2.2 | at least 20 in |
| Sill above the floor | R310.2.3 | at most 44 in |
A grade-floor opening, in the code's definitions, is one whose bottom is not more than 44 inches above or below the finished ground next to it. The clear dimensions are those the window gives when it opens normally, not the size of the frame or of the glass. Meeting the two minimum dimensions is not enough on its own: 24 by 20 inches is only 3.3 square feet. At the minimum height of 24 inches, the opening has to be at least 34.2 inches wide; at the minimum width of 20 inches, at least 41.04 inches tall.
A worked example
A casement window in a bedroom opens to a clear 24 inches wide and 36 inches tall, with its sill 40 inches above the floor. The opening is 24 × 36 ÷ 144 = 6 square feet, more than the 5.7 the code asks for; the height, the width and the sill height are all within the limits, so the window meets the size rules of Section R310.2.
Window wells
Where the bottom of the opening is below the ground outside, Section R310.4 requires an area well, the window well, with at least 9 square feet of horizontal area and a projection from the wall and a width of at least 36 inches each, large enough for the window to open fully. A well deeper than 44 inches needs a permanently attached ladder or steps. Covers, grilles or bars over the well or the window must leave the same clear sizes and open from the inside without a key, a tool or more force than the window itself takes.
Replacement windows
The model code has a Section R310.5 that exempts some replacement windows from the size rules, such as the maker's largest standard window that fits the existing frame, of the same operating style. Seattle did not adopt that exemption. Ask your building department whether yours did before you order a replacement.
Questions people ask
What is the minimum size of an egress window?
Under the 2021 IRC, a net clear opening of 5.7 square feet, or 5 on the grade floor, at least 24 inches high and 20 inches wide, with the sill no more than 44 inches above the floor.
Is a 24 by 36 inch window big enough for egress?
If its clear opening, with the window fully open, is 24 by 36 inches, yes: that is 6 square feet. The frame of such a window is larger than its clear opening, so measure the opening itself.
How big must a window well be?
At least 9 square feet, projecting at least 36 inches from the wall and at least 36 inches wide. If it is deeper than 44 inches, it needs a ladder or steps.
Sources
- 2021 Seattle Residential Code, Chapter 3: Building Planning — the city's edition of the 2021 International Residential Code; Section R310 and, in Chapter 2, the definition of a grade-floor emergency escape and rescue opening
- 2021 Seattle Residential Code, Chapter 2: Definitions — grade-floor emergency escape and rescue opening