Roof & Exterior · Calculator
Downspout Extension Calculator
Enter how far from the wall the water should land, where the downspout ends now and the length of one extension piece. The calculator gives the number of pieces and checks the slope of the ground if you measure it.
Extension pieces
2
- Distance to add
- 4 ft
- Water lands at
- 5 ft from the wall
2021 IRC (Seattle edition), Sections R401.3 and R801.3.
Roof water should land away from the foundation. To reach 5 feet from the wall from an outlet 12 inches out, with 2 foot pieces, you need 2 pieces.
What the code asks for
Two sections of the residential code deal with water near the foundation. Section R801.3 applies where expansive or collapsible soils are known to exist: there, roof drainage has to be collected and discharged to the ground at least 5 feet from the foundation walls, or into an approved drainage system. Section R401.3 applies to every lot: the ground has to slope away from the foundation, falling at least 6 inches within the first 10 feet, and hard surfaces within 10 feet slope at least 2 percent away; where walls, lot lines or slopes make that impossible, drains or swales carry the water away. Surface drainage has to go to a storm sewer or another approved point that does not create a hazard.
Counting the pieces
Measure from the foundation wall to where the downspout outlet ends now, then subtract that from the distance you want. Divide by the length of one extension piece and round up: that is the number of pieces. The calculator also tells you where the water will land with that many pieces.
A worked example
A downspout ends 12 inches from the wall, and the water should land 5 feet out. That leaves 4 feet to cover, so 2 pieces of 2 feet, landing the water 5 feet from the wall. The ground falls 6 inches over the first 10 feet, which meets the code.
Checking the fall
To check the ground, measure how much lower it is 10 feet out than at the wall: a level and a straight board, or a string line, will do. At least 6 inches meets Section R401.3; that is a 5 percent slope.
Questions people ask
How far should a downspout drain from the house?
Where expansive or collapsible soils are known, the residential code asks for roof water to land at least 5 feet from the foundation walls, or go into an approved drainage system. Everywhere, the ground must slope away from the house.
How much should the ground slope away from the foundation?
At least 6 inches of fall within the first 10 feet, a 5 percent slope, under Section R401.3; hard surfaces within 10 feet at least 2 percent.
Sources
- 2021 Seattle Residential Code, Chapter 8: Roof-Ceiling Construction — Section R801.3, roof drainage
- 2021 Seattle Residential Code, Chapter 4: Foundations — Section R401.3, drainage and grade